R32 Logo
ErP_R32 2HP
  • R32 Logo
  • ErP_R32 2HP

Hitachi R32 MonoBloc (4 & 8kW)

List Price: £POA

Product Code: RASM-2VR2E

Enquire about this product

Overview

ECO-FRIENDLY HEAT PUMP FOR HIGH PERFORMANCES

Easy installation

  • Plug & Play: only hydraulic &electrical connections to be done. No refrigerant handling.
  • Easy access to components
  • Included as standard: (2nd circuits, boiler combination, SWP combination etc)

Comfort

  • All-in-one solution: Heating /Cooling / DHW with an external tank
  • High performances all year long
  • Silent outdoor units
  • Compatible with underfloor heating, radiators and fan coils

Controls

  • Latest generation of LCD controller with exclusive functionalities
  • Remote controls and remote maintenance
  • Wide range of room thermostats
  • Exclusive Cascade controller

Best quality

  • Designed and manufactured in JCH factory in Europe
  • HP KEYMARK certification for all models

Savings

  • High seasonal efficiency A+++
  • High efficiency: generates more than 4 times more thermal energy than electrical energy used
  • COP 4.66 and EER 4.8
  • Contributes to reduced energy consumption and, therefore, costs

Higher performances

  • Exclusive technology for higher efficiency
  • Constant power: Heating or Cooling capacities maintained
  • Best working range on the market

 

Technical Spec

Heating Performance

Min / Nom / Max Heating Power (7°C outdoor / 35°C water)kW1.85 / 4.3 / 6.5
Nom / Max Heating Power (-7°C outdoor / 35°C water)kW4.5 / 5.5
Nom / Max Heating Power (-7°C outdoor / 55°C water)kW4 / 4.77
Nominal absorbed heating power (7°C outdoor / 35°C water)kW1
COP (7°C outdoor / 35°C water) according to EN14511-5
SCOP average climate 35°C / 55°C according to EN14825-4.45 / 3.2
Energy label 35°C / 55°C A+++ / A++
Water outlet temperature range (heating mode)°C20 / 60 °C
Maximum water outlet temperature in thermodynamic°C60°C up to-5°C ext

Hydraulic characteristics

Expansion tankl6
Water flow rate (minimum / maximum)m³/h0.5 / 1.9
Heating hydraulic connectionsinch1
Minimum water volume of the installationl28

 

This site uses cookies. By continuing your visit, you accept their use as set out in our Cookie Policy. OK